Measuring Blood Pressure Without a Cuff — Listening to an Artery's Width at the Wrist

Paperis Articles

Measuring Blood Pressure Without a Cuff — Listening to an Artery's Width at the Wrist

Flash short pulses of light into the wrist artery and the blood gives off ultrasound. We follow a method that uses that sound to measure the artery's width and compute blood pressure, up to a proof of principle that compared it with a finger-cuff reference device in 2 healthy volunteers.

🧱Foundations✦AI-generatedEngineering · Nov 20, 2026

Your field's papers, as audio

Pick your fields and journals — Paperis summarizes the key papers and turns them into audio. Listen on your commute.

Start Paperis free →

Measuring Blood Pressure Without a Cuff — Listening to an Artery's Width at the Wrist

One Reading in the Clinic and a Day's Blood Pressure

Blood pressure is usually measured in the clinic by wrapping a cuff around the upper arm. The values measured in this way serve as the benchmark supporting current hypertension classifications and treatment goals, and major academic societies recommend supplementing them with blood pressure measured outside the clinic (PMID 35440738). A single clinic measurement is simply the blood pressure at that specific time and place. Sorting out people whose readings are high only in the clinic, those whose readings are normal only in the clinic, and those whose blood pressure is high only at night represents a typical use case for out-of-office measurement (PMID 24029863).

24-hour ambulatory blood pressure monitoring is a test in which a person goes about their day with a cuff wrapped around their arm, and the cuff automatically inflates at set intervals to measure blood pressure. This test is the gold standard method for measuring nighttime blood pressure, and nighttime blood pressure is strongly linked to cardiovascular risk (PMID 40509714). There is a trade-off, however. The cuff inflates repeatedly, causing discomfort (PMID 41321467) and potentially waking sleeping individuals (PMID 41263383). This is why wearable devices that measure blood pressure throughout the day without squeezing the arm have been studied as an alternative to ease that discomfort (PMID 41321467).

In 2026, a paper addressing this problem with a new approach was published in Nature Communications. Gil Gelbert and Amir Rosenthal from the Faculty of Electrical and Computer Engineering at the Technion – Israel Institute of Technology, along with others, shone short bursts of light into a wrist artery to make the blood inside the artery emit ultrasound, measured the diameter of the artery using that sound, and then converted the diameter into blood pressure (PMID 42897125). The people against whom the blood pressure was checked were 2 healthy volunteers, and the reference standard was a cuff device wrapped around the finger (PMID 42897125).

This article follows that paper to examine why measuring blood pressure without a cuff is difficult, which of those difficulties this approach solved, and what still awaits verification. Devices from specific companies are not evaluated.

What the Cuff Does, and What Cuffless Tries to Do

The oscillometric method is a way of calculating blood pressure by inflating a cuff to press on the artery and then slowly releasing the air while reading the arterial pulsations transmitted to the air inside the cuff. The oscillometric method is the standard approach for automated blood pressure monitors. It eliminated the observer error of the old way where people listened for sounds with a stethoscope, and it made measurement outside the clinic possible (PMID 41193706). Its limitations come from that same spot. The cuff must be inflated, the blood pressure information obtained at one time is sparse, and measurements can only be taken while staying still (PMID 41193706). If you wrap the cuff in the wrong place or the size is wrong, the values get skewed (PMID 35136906).

Cuffless methods usually measure other signals that move along with blood pressure, and use a calculation model to estimate blood pressure from those signals (PMID 42897125). The most common signal is light. Photoplethysmography is a signal that records how the amount of reflected light goes up and down with each pulse when light is shone onto the skin. In a systematic review pooling 16 validation studies (15 types of devices) up to 2019, 81.3% of the devices estimated blood pressure using photoplethysmography (PMID 36713001).

Another long-standing signal is time. Pulse transit time is the time it takes for a pulse pumped by the heart to travel from one point in an artery to another. The relationship between this time and blood pressure depends on the properties of the artery, but those properties cannot be easily measured and change over time. Therefore, the error grows unless it is recalibrated periodically (PMID 34487496).

That mention of recalibration points to a shared wall in this field. Calibration is the task of adjusting the scale that converts the signals read by the device into blood pressure numbers, matching it to that person's actual blood pressure measured with a cuff. Devices that calculate blood pressure indirectly must undergo regular calibration matched to a cuff device (PMID 36865583). There are also approaches that replace calibration with demographic information like age and sex (PMID 40231350). The authors of this paper also note that surrogate signals like photoplethysmography are sensitive to the placement site and require frequent calibration, which has limited their use for blood pressure measurement (PMID 42897125).

Let us imagine a person who finishes calibrating with a cuff in the morning and goes about their day. While blood pressure stays near the value at the time of calibration, the device tracks it well. In a study where 37 people measured for 28 days together with a watch-type device and a validated cuff blood pressure monitor, the watch met the ISO and IEEE accuracy criteria except for one item, and drift over the 28 days was small. In the same study, when the reference blood pressure was 10 mmHg away from the calibration point, the mean difference grew to 3.4 mmHg for systolic and 5.1 mmHg for diastolic, and the authors recommended confirming with a cuff when blood pressure fluctuates greatly or before making diagnosis or treatment decisions (PMID 41602947). In another study of 40 people measured for 24 hours, the watch's systolic blood pressure pulled toward the calibration point so that low values came out higher and high values came out lower, and diastolic blood pressure came out high across the board (PMID 35898281). In a conference abstract of 6 participants, two cuffless devices failed to capture a 12 to 14 mmHg rise in systolic blood pressure measured by a cuff device during a 2-minute cold water stimulation (DOI: 10.1097/01.hjh.0000745628.17305.69).

Posture and people are also variables. In a study measuring 1,125 people, narrowing only to the same posture as during calibration reduced the dispersion of systolic error by 15 to 20% (PMID 35201992). In a study following 3,077 people for about a month, the model using calibration measured diastolic blood pressure well for all participants and systolic blood pressure well for participants with normal blood pressure or younger participants, but performance dropped significantly when older people and those with high blood pressure were mixed in. The authors concluded that to improve accuracy in large groups with mixed people, more signals or principles must be found (PMID 37204948). A 2025 review summarizing these results considers most devices reliable for trends near the last calibration and less reliable for absolute values (DOI: 10.1097/mnh.0000000000001150).

There are also results where photoplethysmography devices followed the flow of blood pressure. In a pilot (feasibility) study where 30 hypertension patients visited four times over 6 weeks, the photoplethysmography device showed no drift over time, and in 83% of cases where systolic blood pressure changed significantly, it pointed in the same direction as the cuff device. The authors added that the variation of the cuff device used as the reference itself was large, so the interpretation should be cautious and confirmed with a larger study (PMID 42775845).

The stance of academic societies remains cautious. A 2022 statement by the European Society of Hypertension working group notes that society guidelines do not recommend cuffless devices for the diagnosis and management of hypertension, concluding that fundamental questions regarding accuracy, performance, and real-world application must be resolved before they can be recommended for clinical practice (PMID 35708294). A 2026 scientific statement also takes the position that accuracy validation is insufficient, so using them for clinical decisions is not recommended (PMID 41739846). The common wall of cuffless measurement is that the scale converting other signals into blood pressure wavers depending on the calibration point, posture, and person.

The Path to Measuring Vessel Diameter

Every time the heart beats, a pressure wave travels down the arteries, changing their diameter (PMID 42897125). Because diameter is a value directly linked to blood pressure, using it alongside validated physiological models can reduce the weaknesses of proxy signals. Shooting ultrasound through the skin and receiving echoes bouncing back from the arterial walls has shown potential for measuring this value (PMID 42897125).

Initially, hand-held probes were used, and now ultrasound patches attached to the skin track the arterial diameters of the limbs and neck, calculating blood pressure waveforms with calibrated mechanical models (PMID 42897125). In prior clinical validation reported in the introduction of this paper, the initial calibration remained valid for up to one year in a healthy human population (PMID 42897125). A 2026 review also notes that wearable ultrasound has been validated for blood pressure measurement across various clinical settings (PMID 42871346).

The wall comes from the size of the echoes. The echoes coming from the front and back walls of the artery are similar in size to the echoes coming from the surrounding tissue, making it difficult to distinguish where the arterial boundary is (PMID 42897125). There are two ways to distinguish them. One is to image the shape of the artery in three dimensions, and the other is to accurately aim the ultrasound beam at the artery. High-definition 3D imaging requires thousands of elements, and aiming a single beam requires maintaining precise attachment placement and orientation (PMID 42897125). The most successful designs to date have lined up elements in a single row and used desktop ultrasound equipment to separately select which element best fits the artery. This array electronically replaces placement, but it remains sensitive to tilt, requiring a skilled practitioner to attach it, and thinner arteries like the wrist require denser and more numerous elements (PMID 42897125).

The method of making sound with light shows blood vessels much more clearly than surrounding tissue, making it a candidate that could alleviate this alignment problem. However, previous patches that made sound with light had weak signals and had to measure only about 1, 10, or 25 times per second, and at this speed, they cannot track blood pressure waveforms. The sound-receiving elements also used the same arrangement as ultrasound patches, inheriting the same complexity and positional sensitivity (PMID 42897125).

Comparison table, "Ways to measure blood pressure without a cuff": five rows by four columns (What it measures / Calibration / Weak points / Validation stage). Upper-arm cuff (oscillometric): inflates then deflates, reading the artery's vibrations in the cuff air / the reference cuffless devices are matched to / must inflate, little information per reading, only at rest, wrong position or size skews the value / standard method of automatic monitors, validated under the cuff standard ISO 81060-2. Photoplethysmography (wrist light sensor): light returning from the skin rises and falls with each pulse and a model estimates pressure / regular calibration to a cuff device / sensitive to placement, drifts away from the calibration point and with posture and person / most cuffless devices in validation studies; societies do not yet recommend it for clinical decisions. Pulse transit time: time for the pulse to travel between two points on an artery / periodic recalibration / its link to pressure depends on artery properties that are hard to measure and change over time / societies do not yet recommend cuffless devices for clinical decisions. Ultrasound patch (echo): wall echoes give the diameter and a calibrated mechanical model gives the pressure waveform / calibrated model; in earlier work the first calibration held up to a year in a healthy group / wall echoes are about as strong as tissue echoes, so 3-D imaging or precise aiming is needed, a linear array is still tilt-sensitive, and wall thickness enters the diameter / earlier clinical validation reported in the paper's introduction; a 2026 review says validated in several clinical settings. This paper (light → sound, optoacoustic, highlighted in blue): the time gap between near- and far-boundary sound from the light-heated blood column gives the inner diameter, then an empirical formula gives pressure / once per person, at rest, alongside a reference device / lab conditions (bench-top lasers, offline processing), seated and still only, the formula is an approximation / proof of principle (2 people), finger-cuff reference device. Footnote: the validation column reflects the literature the article cites, and the lower sensitivity to position and angle was shown in an artery phantom and one volunteer.

Figure: a diagram Paperis drew using only what the article says

When You Shoot Light at It, Blood Makes a Sound

The tip of the Technion researchers' sensor is 3.5 mm thick. A flat bundle of optical fibers shines two streaks of light onto the skin with a 4 mm gap between them, and a single sound-receiving chip sits on a metal partition in the middle (PMID 42897125). What this sensor does is a chain of steps following the wrist artery.

The paper's full Fig. 1 (a–g, original English labels). a: the sensor sits over the radial artery near the wrist and is wired to a console showing a pressure waveform, with the Finapres NOVA reference site on the finger. b, c: the sensor's rotation on the skin (yaw) and the artery's own tilt (pitch). d: the 3.5 mm thick sensor tip with polarization-maintaining fibres, two illumination spots and the SPADE detector between them. e: light diffusing into tissue and ultrasound (US signal) spreading from the artery, with the offset from the artery marked. f: two optoacoustic signals at two moments (T1, T2) of the artery swelling; the width between the two kinks is the diameter D (D = c × Δt), and below, a pressure curve from a BP model. g: the SPADE structure — fibres, elastomer cladding, cavity, waveguide (WG) and substrate, with a 1 mm scale.

Figure: Gelbert et al., Nature Communications 2026, Fig. 1 (all panels a–g), CC BY 4.0. a placement on the wrist and reference site, b–c sensor rotation (yaw) and artery tilt (pitch), d sensor tip, e optoacoustic procedure, f width between the two kinks = diameter, g detector (SPADE) structure. Labels as in the original

The first link is light. A near-infrared laser with an 800 nm wavelength blinks briefly 100 times per second. This wavelength reaches into the artery in the forearm, and 100 times per second is a fast enough rate to track the blood pressure waveform (PMID 42897125). The intensity of the light hitting the skin was within the limits of the American laser safety standards (ANSI) (PMID 42897125).

The second link is sound. The photoacoustic effect is a phenomenon where the part that absorbs a short pulse of light heats up momentarily, and the pressure that rises then spreads out as ultrasound. Among the body's tissues in the visible and near-infrared spectrum, blood absorbs the most light. So, more energy builds up inside the artery than in the surrounding area, the temperature and pressure inside the artery rise momentarily higher than the surroundings, and that pressure becomes a sound that spreads outward (PMID 42897125). That the main share of the sound comes from the blood inside the blood vessel and the share from the vessel wall is small was confirmed in a 2004 animal experiment that recorded sound while washing out the blood vessels of a rabbit's ear with saline solution (PMID 15566172).

The third link is arrival time. Because sound travels through blood at a constant speed, the later a sound arrives, the farther away it came from. When modeling the artery as a cylinder, two sharply bending points appear in the signal, the source of the sound is the entire column of blood inside the artery, the first bend occurs at the near boundary of the blood column (the inner side of the front wall), and the second bend occurs at the far boundary (the inner side of the back wall). The time between the two bends is the diameter divided by the speed of sound in blood (PMID 42897125). Every time the heart beats, the artery swells and shrinks, and every time that happens, this time interval increases and decreases (PMID 42897125). Even in previous research, it was possible to estimate blood vessel diameter using the time between the two peaks of the pressure signal created by light (PMID 15566172).

The fourth link is position. When the detector is shifted sideways from directly above the artery, the arrival time and intensity of the signal change. The interval between the two bends remains the same (PMID 42897125). This calculation assumed a uniformly sounding cylinder and an infinitely small detector. In reality, light becomes weaker the deeper it goes, making the sound from the back wall smaller, but the position of the boundary still remained in the signal (PMID 42897125).

Panels a–c of the paper's Fig. 2 (original English labels). a: an artery drawn as a red circle of diameter D at depth d in tissue — a uniformly emitting cylinder — with ultrasound waves spreading around it, and three detector positions on the surface (blue, yellow, red squares) shifted sideways by Δ. b: an image of the signal with detector position Δ across and normalized time ct down — the arch-shaped band is D thick at every position (two white arrowheads). c: pressure waveforms at the three positions — arrival time and height differ, but the width between the upward kink and the downward kink is D in each.

Figure: Gelbert et al., Nature Communications 2026, Fig. 2, panels a–c, CC BY 4.0. Calculated for a uniformly emitting cylinder and an infinitely small detector. Shifting the detector sideways (Δ) changes only arrival time and strength; the width between the two kinks (D) stays the same. Panels d–f, which add light attenuation, are omitted. Labels as in the original

The property that blood vessel signals are clearer than their surroundings is used here. The signal of a blood vessel isolated near the skin is usually strong enough to exceed all background signals, making it unnecessary to aim the detector precisely or arrange multiple elements. To utilize that advantage, the detector must be small enough to receive sound from all directions. Piezoelectric elements, which are current ultrasound transducer materials, suffer a sharp drop in sensitivity when made that small (PMID 42897125).

The researchers put a light-listening chip in its place. Silicon photonics is a technology that carves pathways for light to travel on a silicon-based chip, handling light inside the chip. This detector (SPADE) carves a ripple pattern into a 1 µm-wide light path made of silicon nitride to create mirrors on both sides, trapping light in a section between them. The top was covered with transparent silicone rubber (PDMS). When the pressure of the sound changes the refractive index of the rubber, the wavelength matched by the trapped light shifts slightly, and that change is read with an interferometer (PMID 42897125). Rosenthal's research team also demonstrated photoacoustic tomography in 2022 using this type of detector coated with a rubber layer that increases sensitivity (DOI: 10.1038/s41467-022-29179-7).

The actual size of the sound-receiving part was about 83 µm long and 1 µm wide. The authors calculated that this detector can be viewed as a single point for sounds with wavelengths longer than 166 µm, and they showed through experiments that this detector, though not infinitely small, is small enough to consistently measure the wrist artery across the tested range of positions and angles (PMID 42897125). There is also a trade-off. The trapped light easily shifts in wavelength even with small temperature and pressure changes, causing it to lose the signal, so the researchers built a separate two-stage feedback system to lock the laser to that wavelength (PMID 42897125).

The final link is the calculation from diameter to blood pressure. The researchers used an empirical formula published by Hayashi et al. in 1980 while measuring the elasticity of human arteries, and this formula is also used by previous ultrasound blood pressure devices. The constants entering the formula were determined once per volunteer by measuring together for 10 seconds in a resting posture with the sensor and reference equipment (PMID 42897125). While the step of measuring diameter was novel, the step of converting diameter into blood pressure still involves calibration adjusted with a cuff device.

Schematic of the measuring principle. Left, a wrist cross-section: two light beams (1) shine from the sensor tip into the skin, with the detector (SPADE, 4) on the partition between them. Below, the artery is drawn as a red blood column inside a thin wall ring, labelled "Blood column (the sound source)" (2), with ultrasound rings spreading around it (3). The top of the column is marked "Near boundary (inside the front wall)" and the bottom "Far boundary (inside the back wall)". Underneath, a graph "Signal at the detector" against arrival time: the signal jumps at the first kink (blue) and dips at the second kink (red), with a "time gap" arrow between them (5). Right, seven links: 1 Light, a near-infrared laser flashes briefly and rapidly onto the skin; 2 Heated blood column, pressure, blood absorbs the most light, heats for an instant and pressure in the artery rises above its surroundings; 3 Ultrasound, that pressure spreads as sound, and the source is the whole blood column; 4 Detector, one chip between the two beams hears the sound with light; 5 Time gap, the first kink comes from the near boundary of the blood column and the second from the far boundary; 6 Diameter, time between kinks × speed of sound in blood = the inner, blood-filled diameter; 7 Blood pressure, the diameter goes into the empirical formula of Hayashi et al., whose constants were set once per person alongside a reference device. Links 1–6 sit in a blue band, "Measuring the diameter (the new part)"; link 7 in a gold band, "Where calibration comes in". Footnote: measuring the diameter was new, but turning it into blood pressure still uses a calibration matched to a cuff device.

Figure: a diagram Paperis drew using only what the article says

The diameter measured this way is the inner diameter filled with blood. Diameters measured with ultrasound echoes mixed in the wall thickness, coming out up to 1 mm larger, and wall thickness can change over time in patients with hypertension (PMID 42897125).

Moved Aside, Turned Around

The researchers first tested with a model imitating the light, sound properties, and shape of a wrist artery. They shifted the sensor sideways from the artery by up to ±10 mm, turned it on the skin by up to 30°, and changed the tilt of the artery up to 10°. In any direction, the standard deviation of the diameter was about 10 µm, and the authors calculated that this scatter translates to 3.3 mmHg in blood pressure terms (PMID 42897125). In the same model, when receiving photoacoustic signals with a single piezoelectric element, the diameter could be measured only within ±5 mm, and the signal was distorted even with a 5° turn. Even with perfect alignment, the standard deviation was 20 µm, and beyond 10° it sometimes exceeded 100 µm (PMID 42897125). The light also followed the shifted distance. Beneath a tissue-mimicking 4 mm thick plate, two light beams spread into one, reaching the artery even when the sensor was shifted by ±10 mm (PMID 42897125).

On a human wrist, testing was done with one volunteer (a 29-year-old male). The starting point was set by feeling the pulse with a hand, a process that usually took less than 10 seconds. During the measurement, the sensor was pushed across the arm by about ±5 mm and turned by up to 30° (PMID 42897125). At the fixed position, the standard deviation of the diameter was 52 µm for diastole and 36 µm for systole, and the authors explain this scatter as normal blood pressure variation occurring from beat to beat. While pushing the sensor, it remained similar at 40 µm and 36 µm (PMID 42897125).

In measurements where the angle was turned in four steps from 0° to 30°, the standard deviation of the diameter for this sensor was 47 µm for diastole and 28 µm for systole. At the same spot, receiving photoacoustic signals with a single piezoelectric element yielded 109 µm and 82 µm, and receiving ultrasound echoes with a piezoelectric element yielded 218 µm and 190 µm (PMID 42897125). With the echo method, shifting by just 0.3 mm caused a diameter error of about 200 µm (PMID 42897125). The effect of changing position and angle in the human body was smaller than the diameter variation from beat to beat, so that effect alone could not be measured separately as a number (PMID 42897125). The property of being less sensitive to position and angle is a result shown in an artery model and a single volunteer.

The paper's full Fig. 5 (a–l, original English labels). Three columns show M-mode images of the same volunteer's wrist artery (a 29-year-old man) measured three ways: left, Optoacoustic SPADE (this paper's sensor); middle, Optoacoustic Piezo (optoacoustics received by a single piezoelectric element); right, Pulse Echo Ultrasound (ultrasound echoes from a piezoelectric element). Four rows are sensor rotations on the skin of 0°, 10°, 20° and 30° (yaw). Each panel overlays systolic and diastolic diameters (DSys, DDia), a yellow diameter trace and a cyan raw signal. Column headers give diameter standard deviations: SPADE 28 µm systolic and 47 µm diastolic, Piezo 82 and 109 µm, Pulse Echo 190 and 218 µm. Time axis 0–5 s.

Figure: Gelbert et al., Nature Communications 2026, Fig. 5 (all panels a–l), CC BY 4.0. One volunteer's wrist artery (a 29-year-old man) measured while the sensor was rotated from 0° to 30°. From left: this paper's sensor (SPADE), optoacoustics received by a single piezoelectric element, and ultrasound echoes from a piezoelectric element. Labels as in the original

Two People, Three Months, 120 Times

Two volunteers participated in the blood pressure comparison. One was a 29-year-old male with slightly higher blood pressure, and the other was a 42-year-old female with slightly lower blood pressure, whom the authors call healthy volunteers (PMID 42897125). The reference device was a Finapres NOVA. This is a device that wraps a small cuff around the finger to produce the entire blood pressure waveform in real time, and it has been approved by the U.S. Food and Drug Administration (FDA). The researchers calibrated this device with an upper-arm cuff in each session, and converted the finger waveform into an upper-arm waveform and then back into a wrist artery waveform through calculation (PMID 42897125). The error of this transformation, which reconstructs upper-arm blood pressure from finger pressure, was reported in a previous study as 3±8 mmHg for systolic and 4±6 mmHg for diastolic (PMID 42897125). This means there is an error in the reference itself.

Measurements were taken with the hand kept still at heart height, in a sitting-at-rest posture and a sitting-while-bracing-the-torso posture. Each measurement lasted 14 seconds with 10 seconds used, for a total of 120 times over three months. Calibration was done only once per person at the start of the study in the resting posture, and the sensor was removed at the end of each session and reattached for the next session in roughly the same spot without precise placement guidance (PMID 42897125). The authors explain that this condition mimics the positional and angular uncertainty that would occur in a real wearable device (PMID 42897125).

Panels f and i of the paper's Fig. 6 side by side (original English labels). Left, f: a scatter plot with NOVA BP (the reference device, mmHg) across and this sensor's pressure up; diastolic (yellow) and systolic (dark red) points for the man (circles, M) and the woman (triangles, F) lie along the diagonal, with mean 0.20 and red dashed 95% limits of +9.05 and −8.65. Right, i: a Bland–Altman plot of the difference against the average of the two devices; diastolic mean −0.26 (limits +5.89, −6.41), systolic mean 0.66 (limits +12.22, −10.90). Each point is the average of a 10-second measurement, 120 in all.

Figure: Gelbert et al., Nature Communications 2026, Fig. 6, panels f (scatter plot) and i (Bland–Altman), CC BY 4.0. n=120, 2 volunteers, finger-cuff reference device (NOVA). Each point averages a 10-second measurement; calibration was done once per person at the start of the study. Labels as in the original

The mean absolute difference across the 120 measurements was 2.6 mmHg for diastolic and 4.7 mmHg for systolic, with the combined average of the two being 3.6 mmHg (PMID 42897125). In the posture where the torso was braced, blood pressure went up for both devices, and in the representative waveforms shown, an entire single heartbeat between the high and low numbers overlapped with the reference device. The male volunteer's continuous measurement of over 30 minutes was done several days after calibration. The authors noted that the blood pressure measured by the reference device was widely spread, evaluating values far from the calibration point. This is the distribution within two people (PMID 42897125).

The authors wrote that this value falls within "the range associated with high-grade device performance", and that it is comparable to the values reported for a wearable ultrasound patch in a study with a similar number of participants (PMID 42897125). This evaluation is an expression by the authors stemming from a comparison of 2 healthy volunteers against a finger-cuff device, and it does not mean that it has passed standard validation which requires multiple people and various blood pressure ranges. The authors also noted in the same paper that they call this study a preliminary proof-of-concept study with n=2, and that whether it fully satisfies recent validation standards must be shown in a larger clinical study (PMID 42897125).

The sources of error pointed out by the authors are three. The empirical formula converting diameter to blood pressure is an approximation, the inaccuracy of the reference device, and the force with which the patch fixing the sensor presses against the wrist (PMID 42897125). The conditions of the experiment were also laboratory conditions. The laser that emits light and the laser that reads the chip were both tabletop equipment, and the volunteer wore laser safety glasses. The signals were not turned into blood pressure in real time but were processed later in 10-second units, and during that process, a human checked and corrected about 5% of the automated steps that find the artery boundary (PMID 42897125). Measurements were limited to a seated, motionless posture following American Heart Association guidelines (PMID 42897125).

“Verification” Involves Headcounts and Conditions

There is a set procedure to the saying that a blood pressure monitor is verified. For cuff blood pressure monitors, there is the international standard ISO 81060-2 jointly created in 2018 by the Association for the Advancement of Medical Instrumentation (AAMI), the European Society of Hypertension, and the International Organization for Standardization (ISO), and because this standard is for cuff devices, it does not fit the verification of cuffless devices (PMID 42853222). Verification studies following this standard have been carried out by gathering 85 people (PMID 41263383; PMID 36561062), and people with normal blood pressure and abnormal blood pressure are gathered in the proportions set by the standard (PMID 38187511). One of the passing lines is an average difference from the standard within ±5 mmHg and a standard deviation of that difference of 8 mmHg or less (PMID 36561062), and there is one more standard judged per person (PMID 38187511). Because this passing line is a yardstick that looks at the average difference and its standard deviation, it is not the same index as the mean absolute difference that this paper produced (diastolic 2.6, systolic 4.7 mmHg). One cannot read 4.7 as falling within the passing line just because it is smaller than 5.

Cuffless devices have more things that must be examined separately. The Institute of Electrical and Electronics Engineers (IEEE) defined wearable cuffless blood pressure monitors in the 2014 standard IEEE 1708 and set methods to objectively evaluate their performance (PMID 26665952). A 2022 statement by a European Society of Hypertension working group noted that the verification of cuffless devices must deal with whether individual cuff calibration is necessary, how well the measurement holds up after calibration, and whether it tracks changes in blood pressure (PMID 35708294). This working group's 2023 recommendation targeting cuffless devices that measure with intervals exceeding 30 seconds set six tests. They are accuracy when resting, when changing device height, when blood pressure drops from treatment, when awake and when sleeping, when blood pressure rises from exercise, and whether accuracy is maintained before recalibrating. The tests needed vary depending on whether the device demands calibration and whether it measures in multiple postures (PMID 37303198).

This paper analyzed blood pressure results according to the 2019 revision of IEEE 1708 (IEEE 1708a) (PMID 42897125). The analysis framework followed the standard, the people were 2, and the postures were two sitting ones. The authors stated that they are targeting participants exceeding 85 in the full-scale clinical verification of the next step (PMID 42897125). A 2021 review warned that papers on cuffless device accuracy with inadequate methods and conclusions that can invite misunderstanding are increasing (PMID 34510915). What this paper showed is a principle. It is that light-generated sound can measure the diameter of a wrist artery less sensitively to location, and that the blood pressure calculated from that diameter in two people was close to the reference equipment.

From the Laser on the Desk to the Wrist

The authors detailed the path toward a wrist-worn device. The laser used to shine light in this experiment was a bulky tunable wavelength instrument, but the energy hitting the skin was small at 4.9 mJ per pulse and the signal exceeded the required level. The authors believe that a small laser diode array operating at a single wavelength like 808 nm could achieve similar performance. The chip reading device can be built directly inside the chip, and because there is only a single sound-receiving element, the signal-receiving electronic circuit also becomes simpler than the multi-channel devices of ultrasound patches, according to the authors' outlook (PMID 42897125).

There is also work remaining on the computational side. This sensor provides the entire blood pressure waveform between the high and low numbers, but this study did not use that information. The authors note that using the waveform shape can estimate blood pressure more robustly, and that there is an example from another study where the calibration constant of Hayashi's empirical formula was directly estimated from the features of the diameter waveform (PMID 42897125). Uncalibrated estimation is a possibility that has not yet been tested with this sensor.

The clinical challenges are greater. Full-scale validation with more than 85 people, analysis of sex differences, and measurement during motion remain. The authors argue that the structure is suited for motion as well, citing the point that the diameter did not wobble even while pushing the sensor, but this blood pressure comparison was done only in a seated, motionless posture (PMID 42897125). Nighttime blood pressure is a homework assignment for the entire field. In a meta-analysis gathering studies from 2019 to 2024, current cuffless devices were similar to 24-hour ambulatory blood pressure monitoring for daytime blood pressure, but deviated by about 4.5 mmHg in systolic and 5.6 mmHg in diastolic at night. In the same analysis, photoplethysmography devices showed a tendency to be better than other technologies, and the authors stated this result as an exploratory finding to be confirmed by larger studies (PMID 41321467).

We have reached the point of listening to the sound made by the artery on the wrist and measuring its diameter with that sound. Whether that diameter can be read reliably as the blood pressure of various people is a task for validation after securing the number of people and conditions to answer.

Where to Look Further

  • “What Blood Pressure Measures — Two Numbers, and an Answer That Changes With Where You Measure” — Why clinic, home, and 24-hour measurements yield different numbers, and what the high and low numbers point to.
  • European Society of Hypertension Working Group recommendations on cuffless device validation (2023) — What each of the six tests asks (PMID 37303198).
  • A 2026 review placing cuff oscillometry, watch-type cuff devices, and cuffless devices side by side (PMID 41193706).
  • An open question still is whether a calibration set once for an individual holds up across different people, different blood pressure ranges, and months of time and movement.

Source Papers

  • "Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoring." (2026) — PMID 42897125 — Measured wrist artery diameter at 100 Hz using photoacoustic excitation and a silicon-photonics single detector, demonstrating position and rotation tolerance. Blood pressure comparison with 2 volunteers and 120 trials against Finapres NOVA showed MAD diastolic 2.6 and systolic 4.7 mmHg. The authors note this is a proof of principle with n=2, and full standards compliance remains a task for larger studies.
  • "Blood pressure and its variability: classic and novel measurement techniques." (2022) — PMID 35440738 — Office upper-arm cuffs serve as the standard for classification and treatment targets, while all major societies recommend out-of-office measurements. The accuracy and utility of cuffless devices remain uncertain.
  • "European Society of Hypertension position paper on ambulatory blood pressure monitoring." (2013) — PMID 24029863 — Indications for 24-hour monitoring include white-coat phenomenon, masked hypertension, and nocturnal hypertension.
  • "Nocturnal blood pressure: pathophysiology, measurement and clinical implications. Position paper of the European Society of Hypertension." (2025) — PMID 40509714 — Nighttime blood pressure is strongly associated with cardiovascular risk, with 24-hour monitoring as the standard method, while cuffless technology requires further validation.
  • "Comparing the accuracy of continuous blood pressure monitoring using wearable cuffless devices with conventional 24-hour ambulatory blood pressure monitoring: A systematic review and meta-analysis." (2025) — PMID 41321467 — Discomfort of repeated cuff inflation. Wearable cuffless devices perform similarly during the day but deviate at night (systolic 4.48 and diastolic 5.64 mmHg). PPG superiority is exploratory.
  • "Accuracy and Reduced Sleep Disruption of a Wearable Smartwatch for Nocturnal Blood Pressure Monitoring: A Validation Study." (2025) — PMID 41263383 — Traditional 24-hour monitoring can disrupt sleep. Validated a wrist-worn oscillometric device in 85 individuals according to ISO 81060-2.
  • "The quest for accurate wearable blood pressure monitors." (2026) — PMID 41193706 — Cuff oscillometry is the standard, but has limitations of cuffs, stationary conditions, and restricted information. No cuffless technology has persuasive evidence of clinical-grade accuracy, and medical societies do not recommend them.
  • "Cuffless Blood Pressure Devices." (2022) — PMID 35136906 — Cuffs are poorly tolerated for repeated measurements, and position and size errors skew readings.
  • "Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis." (2022) — PMID 36713001 — Among 16 papers and 15 device types, 81.3% use PPG. Inconsistent standards and validation methods make comparison difficult.
  • "Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration Models." (2022) — PMID 34487496 — Pulse transit time estimation relies on unmeasurable arterial properties; when these properties change, errors grow, requiring periodic calibration.
  • "Validating cuffless continuous blood pressure monitoring devices." (2023) — PMID 36865583 — Devices that indirectly calculate blood pressure must be periodically calibrated against cuff devices. Regulation lags behind the pace of innovation.
  • "Cuffless Blood Pressure Measurement: Where Do We Actually Stand?" (2025) — PMID 40231350 — Most require user calibration using cuffs or demographic information. There is no solid evidence that pulse analysis or pulse arrival time provides accuracy beyond the calibration value.
  • "Long-term accuracy and stability of blood pressure measurements from a smartwatch: Prospective validation study." (2026) — PMID 41602947 — In 37 participants over 28 days, ISO and IEEE criteria were met except for one item, showing good long-term stability. When deviating 10 mmHg from the calibration point, the mean difference increased to 3.4/5.1 mmHg; cuff confirmation is recommended for large fluctuations or before diagnosis.
  • "Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient Accuracy." (2022) — PMID 35898281 — In 40 participants over 24 hours, systematic bias pulled readings toward the calibration point (overestimating low blood pressure and underestimating high blood pressure).
  • "CUFFLESS BLOOD PRESSURE DEVICES AND INCONSISTENT TRACKING OF BLOOD PRESSURE CHANGES" (2021) — DOI: 10.1097/01.hjh.0000745628.17305.69 — Conference abstract. In a cold pressor test (3 individuals per device), two cuffless devices failed to capture blood pressure increases. Single-point calibration is advantageous only when returning to that exact point.
  • "A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory Setting." (2022) — PMID 35201992 — 1,125 participants. Restricting the calibration posture reduces systolic error standard deviation by 15 to 20%. Reference type, posture, and environment affect error.
  • "Cuffless Blood Pressure Measurement Using Smartwatches: A Large-Scale Validation Study." (2023) — PMID 37204948 — 3,077 participants. The calibration model performs well for overall diastole and normotensive, younger individuals, but degrades significantly when older adults and hypertension patients are mixed in. Uncalibrated measurement is limited.
  • "Cuffless blood pressure in 2025: from promise to practice: a narrative review" (2025) — DOI: 10.1097/mnh.0000000000001150 — Mostly proxy signals and periodic calibration; trends near the last calibration are reliable, but absolute values are less so.
  • "Long-term stability and blood pressure change tracking with a cuffless wearable device in hypertensive patients." (2026) — PMID 42775845 — In 30 hypertension patients over 6 weeks, no drift was observed and the direction of large changes matched in 83 of 86% cases. High variance in the reference device warrants cautious interpretation, and larger studies are needed.
  • "Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability." (2022) — PMID 35708294 — ESH guidelines do not recommend cuffless devices for diagnosis or management. Validation must address the need for calibration, post-calibration stability, and change tracking. IEEE 2014 standards exist, and ISO is under development.
  • "Cuffless Blood Pressure Monitoring Devices: Technical Foundations and Clinical Implications." (2026) — PMID 41739846 — Science advisory. Lack of accuracy validation advises against use for clinical decisions.
  • "Vascular Phenotyping with Photoacoustic and Ultrasound Imaging in Cardiovascular Disease: Recent Innovations." (2026) — PMID 42871346 — Wearable ultrasound has been validated for blood pressure measurement across various clinical settings.
  • "Photoacoustic determination of blood vessel diameter." (2004) — PMID 15566172 — Estimated vessel diameter using the time between pressure signal peaks. Saline washes confirmed that blood inside the vessel accounts for the majority of the signal.
  • "Silicon-photonics acoustic detector for optoacoustic micro-tomography" (2022) — DOI: 10.1038/s41467-022-29179-7 — Achieved optoacoustic tomography below 20 µm using a silicon-photonics resonator detector coated with an elastic material to increase sensitivity.
  • "Updated practical guide for validation studies of automated cuff blood pressure monitors according to the Universal Standard ... (ISO 81060-2:2018) and Amendments 1:2020 and 2:2024." (2026) — PMID 42853222 — ISO 81060-2 is designed for cuff devices and is unsuitable for cuffless devices.
  • "Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressure." (2022) — PMID 36561062 — Validated a watch-type cuff sphygmomanometer using ISO 81060-2 (85 resting participants). Passing thresholds are a mean within ±5 and standard deviation within 8 mmHg.
  • "Is the Blood Pressure-Enabled Smartwatch Ready to Drive Precision Medicine? Supporting Findings From a Validation Study." (2023) — PMID 38187511 — Allocated and sampled normal and abnormal blood pressure patients according to ISO 81060-2 guidelines.
  • "[Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices]." (2015) — PMID 26665952 — IEEE 1708-2014 establishes definitions and objective performance evaluations for wearable cuffless blood pressure monitors.
  • "European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devices." (2023) — PMID 37303198 — Six validation tests for intermittent cuffless devices (stationary, device position, treatment, wake/sleep, exercise, recalibration); required tests vary by device characteristics.
  • "Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals." (2021) — PMID 34510915 — Warns that ISO universal standards are unsuitable for cuffless devices, alongside a rising publication of inappropriate methods and misleading conclusions.
Sources (30)
  • Silicon-photonics optoacoustic sensor for fully wearable blood pressure monitoringPMID 42897125
  • Blood pressure and its variability: classic and novel measurement techniquesPMID 35440738
  • European Society of Hypertension position paper on ambulatory blood pressure monitoringPMID 24029863
  • Nocturnal blood pressure: pathophysiology, measurement and clinical implications. Position paper of the European Society of HypertensionPMID 40509714
  • Comparing the accuracy of continuous blood pressure monitoring using wearable cuffless devices with conventional 24-hour ambulatory blood pressure monitoring: A systematic review and meta-analysisPMID 41321467
  • Accuracy and Reduced Sleep Disruption of a Wearable Smartwatch for Nocturnal Blood Pressure Monitoring: A Validation StudyPMID 41263383
  • The quest for accurate wearable blood pressure monitorsPMID 41193706
  • Cuffless Blood Pressure DevicesPMID 35136906
  • Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysisPMID 36713001
  • Noninvasive Continuous Blood Pressure Estimation From Pulse Transit Time: A Review of the Calibration ModelsPMID 34487496
  • Validating cuffless continuous blood pressure monitoring devicesPMID 36865583
  • Cuffless Blood Pressure Measurement: Where Do We Actually Stand?PMID 40231350
  • Long-term accuracy and stability of blood pressure measurements from a smartwatch: Prospective validation studyPMID 41602947
  • Smartwatch-Based Blood Pressure Measurement Demonstrates Insufficient AccuracyPMID 35898281
  • CUFFLESS BLOOD PRESSURE DEVICES AND INCONSISTENT TRACKING OF BLOOD PRESSURE CHANGESDOI 10.1097/01.hjh.0000745628.17305.69
  • A Comparison of Wearable Tonometry, Photoplethysmography, and Electrocardiography for Cuffless Measurement of Blood Pressure in an Ambulatory SettingPMID 35201992
  • Cuffless Blood Pressure Measurement Using Smartwatches: A Large-Scale Validation StudyPMID 37204948
  • Cuffless blood pressure in 2025: from promise to practice: a narrative reviewDOI 10.1097/mnh.0000000000001150
  • Long-term stability and blood pressure change tracking with a cuffless wearable device in hypertensive patientsPMID 42775845
  • Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular VariabilityPMID 35708294
  • Cuffless Blood Pressure Monitoring Devices: Technical Foundations and Clinical ImplicationsPMID 41739846
  • Vascular Phenotyping with Photoacoustic and Ultrasound Imaging in Cardiovascular Disease: Recent InnovationsPMID 42871346
  • Photoacoustic determination of blood vessel diameterPMID 15566172
  • Silicon-photonics acoustic detector for optoacoustic micro-tomographyDOI 10.1038/s41467-022-29179-7
  • Updated practical guide for validation studies of automated cuff blood pressure monitors according to the Universal Standard ... (ISO 81060-2:2018) and Amendments 1:2020 and 2:2024PMID 42853222
  • Validating the accuracy of a multifunctional smartwatch sphygmomanometer to monitor blood pressurePMID 36561062
  • Is the Blood Pressure-Enabled Smartwatch Ready to Drive Precision Medicine? Supporting Findings From a Validation StudyPMID 38187511
  • [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices]PMID 26665952
  • European Society of Hypertension recommendations for the validation of cuffless blood pressure measuring devicesPMID 37303198
  • Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and ProposalsPMID 34510915

This article is AI-generated from research papers for general information and does not replace professional advice. Send an objection, addition or error

© 2026 Neokuns (Paperis). Sharing links is welcome; republishing the full text requires prior permission.